452
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
6.9.5
Messages
The controller messages of the VW-XML protocol are implemented as required in chapter 4.3
"Messages/SST-controller" of the VW-corporate requirement specifications. Special features for
adjusting the
Rexroth Tightening System 350
are available for individual controller messages.
Channel number <KNR>
In VW-XML, the channel number is used to address certain channels explicitly.
In single-channel operation with the compact system, channel number assignment is optional. However,
it is possible to address the compact system using channel number 1.
A single tightening channel of the modular system is identified as follows:
Tool release <TOL>
In order to be able to release or disable the tool of a certain channel via VW-XML, the signal
•
"Enable" (
En
) must be applied to the "XML" PLC-module in the compact system; see table
;
•
"Enable of the particular channel (
CH x.y En
) must be applied to the "XML" PLC-module in the
modular system; see table
.
Loosen disable <LSN>
In order to be able to release or disable loosening of a certain channel via VW-XML, the signal
•
"Block Loosen" (
CcwLock
) must be applied to the "XML" PLC-module in the compact system; see
table
.
•
"Block Loosen" of the particular channel (
CH x.y CcwLock
) must be applied to the "XML"
PLC-module in the modular system; see table
Start <STR>
In order to be able to start the tightening spindle of a certain channel via VW-XML, the signal
•
"Start signal" (
Cw
) must be applied to the "XML" PLC-module in the compact system; see table
•
"Start signal" of the particular channel (
CH x.y Cw
) must be applied to the "VW-XML" PLC-module
in the modular system; see table
Program selection <PRS>
In order to be able to select the tightening program of a certain channel via VW-XML, the signal
•
S for program selection (
Prg0…Prg7
) must be applied to the "XML" PLC-module in the compact
system; see table
•
S for program selection of the particular channel (
CH x.y Prg0…CH x.y Prg7
) must be applied to the
"XML" PLC-module in the modular system; see table
Group selection <GRP>
In order to be able to display and use all functions of a modular system with eight (8) application blocks
and 48 parameterizable applications VW-XML, the group number (GNR) has to be coded. If the number
of NOK group events is reached, the application block is disabled.
Group number for application block 1:
KNR
Rack 6 slot
+
=
Example
For a modular system, this assignment means that a channel in slot 3 of rack 2 is addressed using
channel number 15.
GNR
Applicationnumber
=
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...