3 608 878 300
Tightening Technology |
Bosch Rexroth AG 457
System 350
| 3 608 878 300/2019-03
6.10.2
Settings in the BS350 operating system
The Rexroth IPM Protocol is configured on the compact system and the KE in an identical way. The
following settings have to be made in the BS350 operating system in the specified order:
1.
Configuration of Rexroth IPM Protocol
2.
"Select ID-code filter" dialog
6.10.2.1
Configuration of Rexroth IPM Protocol
The configuration window for Rexroth IPM Protocol in the BS350 operating system can be opened in two
different ways. This depends on the question whether the BS350 is connected to a tightening system
("online") or not ("offline"):
•
Online: As of version V2.500 of the
Rexroth Tightening System 350
:
System
IPM configuration
If no configuration file is stored on the tightening controller, the following message is output and the
configuration window is not opened:
There is no IPM configuration file available on the controller. The configuration view cannot be
opened.
•
Offline: As of version V2.500 of the
Rexroth Tightening System 350
:
File
New
IPM
configuration
Configuration files for Rexroth IPM Protocol with
ipm
filename extension can be opened
(
File
Open…
), saved (
File
Save…
or
File
Save As…
) and printed in the BS350-specific report
format (
File
).
The title bar of the configuration window for Rexroth IPM Protocol in the BS350 operating system differs
according to the operating mode:
•
In the online mode, the name of the title bar is
IPM configuration: CS
for compact systems or
IPM
configuration: KE
for modular systems.
•
In the offline mode, the name of the title bar is
IPM configuration: New1, New2, …
The fields in the entry window have the following meanings:
Table 6–141:
Configuration settings Rexroth IPM Protocol
Element
Type
Value range
Standard value
Comment
Host IP address
Text; read-only
local
local
IPM IP address
TCP/IP V4 address TCP/IP V4 address 192.168.0.1
IP address of the IPM gateway
to which the data is to be sent
(target address)
IPM port
TCP/IP V4 port
TCP/IP V4 port
5501
IP port of the IPM gateway to
which the data is to be sent
(target address)
Up to V2.400
ID code mask
Text
maximally 255
characters
–
The IPM data record has
different (text) data fields to
which flexible parts of the
ID-code can be mapped, see
example
element can be used for this
purpose, whereas the following
characters are admissible for ID
code mask (IDCodeMask):
– _
Placeholder; character at
this position is ignored
– *
New placeholder character
to provide a clearer view
– I
Character at the position
marked by I is taken over in
IPM ID code
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...