470
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
The
PLC assignment table of the control unit (SE)
must be deleted if an update of firmware versions
< V2.200 has been performed and the RPA interface is to be used, see figure
. In the PLC
assignment table of the SE, there is no RPA filter, i.e. the corresponding signals have already been
assigned by means of default. In other words: configuration for RPA is not necessary.
Fig. 6–75:
Delete PLC assignment table for firmware update < V2.2
NOTE
Danger to RPA functionality!
The RPA-functionality is jeopardized by wrong signal assignment.
Make sure that the sane RPA tightening channel is assigned to the input and the output.
After the sequence tests at a control with RPA, all components of the rack for the tightening
controller and the communication unit have to be reset (Reset-button).