498
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
6.12.5.3
PLUS signals timing diagram
The following sequence diagram indicates the general sequence of PLUS communication in the "Work
and Send" (WaS):
Fig. 6–76:
Timing diagram of PLUS communication in "Work and Send" operating mode
6.12.5.4
Timing diagram for system errors
As the PLC interface has only one 16-bit word for transmission of one channel error code, the errors
active in the system are transmitted multiplexed via the interface. For this purpose, the error code and the
channel number are generated by the KE and the
ChnErr signal
is set while waiting for acknowledgement
of acceptance by the PLC by the rising edge at
ChnErrAck
. With this, the error is transmitted into the
PLC. The KE removes the signal again and waits for confirmation by the PLC (falling edge of
ChnErrAck
).
If additional errors are active, they are transmitted respectively. If no more error is active, error code 0 is
transmitted.
Fig. 6–77:
Timing diagram of PLUS communication for system errors
(1)
Data memory (internal)
(1a)
Data deleted
(1b)
Data for pos 1
(1c)
Data for pos 1 and pos 2
(1d)
Data deleted
______|¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯|____ InPos
_____________________________________________________________________|¯¯¯¯¯¯¯|________ StartReport
-----|¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯|---- ID_Number
-----|¯¯¯|---------------------------------------------------------------------------- TypNo
------------|¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯|--------------|¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯|---------------------- Fox_PosNo
_______________|¯¯¯¯¯¯¯¯¯¯¯¯|_________________|¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯|______________________ FOx_Cw/Ccw
200ms 200ms
________|¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯|_ AckInPos
________|¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯|_ AckTypOk
_______________________________________________________________________|¯¯¯¯¯¯¯¯|_____ AckReportStart
____________________________________________________________________________|¯¯¯|_____ ReportOk
____________________________________________________________________________|¯¯¯|_____ ReportNok
__________________________________________________________________________|¯¯¯¯¯|_____ ErrorCode
------ ¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯ ¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯ ¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯ ¯¯¯¯ (1)
Pos 1
Pos 2
(1a) (1b)
(1c)
(1d)
(1)
Error code for channel 0.1
(2)
Error code for channel 0.2
(3)
Error class for channel 0.1
(4)
Error class for channel 0.2
(5)
1 (channel 0.1)
(6)
2 (channel 0.2)
Note:
If Chn_ErrCode = 0, no more error is active.
________|¯¯¯¯¯¯¯¯¯¯¯¯|___________|¯¯¯¯¯¯¯¯¯|____
ChnErr
------ ¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯ ¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯
Ch_ErrCode
------ ¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯ ¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯
Ch_ErrClass
------ ¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯ ¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯¯
Ch_ChnNum
______________|¯¯¯¯¯¯¯¯¯¯|___________|¯¯¯¯¯¯¯¯|_
ChnErrAck
(1)
(3)
(5)
(2)
(4)
(6)
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...