BS350 configuration
For calculation of average values, the tightening programs have to be respectively prepared. Precisely two
tightening steps have to be defined for individual measurements. These tightening steps have to fulfill the
following requirements:
•
The tightening steps require type "extended" and the
Torque average value
monitoring function.
•
Under
Save results,
Docu buffer
has to be selected. Each docu buffer number (1-10) can be
selected.
•
Under
Tightening step category
, the
10: Function E
has to be selected (this can be adjusted in the
IL project if necessary).
The QDA configuration is executed as standard application
6.13.3.2
Editing the QDA template file via BS350
The QDA template file required for configuration can be processed via BS350 under
Extras
IL
configuration
:
1.
In window
IL configuration
select the file
qda-template.ini
.
2.
Edit the parameters.
3.
Click
Send
to apply the changes to the tightening system.
For further information, refer to section
Total calculation of the QDA average torque value via integrated
, see "Project planning" documentation of the Rexroth Tightening System 350.
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...