3 608 878 300
Tightening Technology |
Bosch Rexroth AG 527
System 350
| 3 608 878 300/2019-03
7.2.5
Interface modules (IM)
Data communication (data services) and control signal exchange with the partner controller are
implemented by interface modules (IM).
Fig. 7–3:
Possible interfaces A, B1 and B2 on CS351/SE352M/KE350(G IL)
To insert the interface modules:
Slide the interface module into the top and bottom guide rails of the respective slot as far as it will
go and then secure the same using the corresponding knurled bolts at the front.
Slots in CS351/SE352M/KE350G IL
Detailed information on admissible interface module can be found in table 6-1.
.
17
9
1
24
C5 C4
C2
C3
C1
16
8
X7E1
X3U1
X3U2
XDN1
X6C1
X3C1
XDVI
X3U4
X3U3
Reset
B2
B1
A
NOK
OK
FG
Rexroth
CS351
Reset
B1
B1
1
X
3
U
1
X
3
U
2
X
3
U
3
2
B 1
B 2
R es et
X
3
C
1
X
3
U
4
X
D
V
I
X
7
E
1
K E 350G IL
X
3
U
1
X
3
U
2
X
3
U
3
A
R UN/S T O P
E R R O R
1
2
3
2
2
3
1
Interface A
Interface B1
Interface B2
1
2
3
Detailed information on the data communication can be found in chapter
.
Detailed information on the control signal exchange can be found in chapter
NOTICE
Open slots
Open slots may lead to system damages.
Close all free slots with dummy plates.
Interface modules do not always have to be used. In this case, close the empty slots using dummy plates.
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...