3 608 878 300
Tightening Technology |
Bosch Rexroth AG 533
System 350
| 3 608 878 300/2019-03
Fig. 7–8:
X1N4 voltage selection terminals with connection groups G1, G2, and G3
NOTICE
Varying assignment of connections within a group
Device destruction
Only the connections of one group may be used.
Do not simultaneously assign varying groups.
NOTICE
Incorrect wiring
Damages to the control and power electronics
Always feed the mains connection through the upper terminal strip (see Table
The lower terminal strip must remain fully wired.
Table 7–5:
Voltage selection terminals
Pin
Signal
Description
Voltage/current
1
PE
PE wire
PE potential
G1
2
L1
L1 mains connection
380 V~ – 415 V~ / 4.6 A
3
L2
L2 mains connection
380 V~ – 415 V~ / 4.6 A
4
L3
L3 mains connection
380 V~ – 415 V~ / 4.6 A
G2
5
L1
L1 mains connection
440 V~ – 480 V~ / 3.9 A
6
L2
L2 mains connection
440 V~ – 480 V~ / 3.9 A
7
L3
L3 mains connection
440 V~ – 480 V~ / 3.9 A
G3
8
L1
L1 mains connection
500 V~ / 3.5 A
9
L2
L2 mains connection
500 V~ / 3.5 A
10
L3
L3 mains connection
500 V~ / 3.5 A
G4
11
L1
L1 device connection
230 V~ / 7.5 A
12
L2
L2 device connection
230 V~ / 7.5 A
13
L3
L3 device connection
230 V~ / 7.5 A
}
.1
.2
.1
.2
.1
.2
.3
.4
1
.1
.2
.1
.2
.1
.2
.1
.2
.1
.2
.1
.2
.1
.2
2
3
4
5
6
7
8
9
10
.1
.2
.1
.2
.1
.2
11
12
13
G1 G2
G3
G4
Terminal strips for mains connection
Device connection
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...