3 608 878 300
Tightening Technology |
Bosch Rexroth AG 545
System 350
| 3 608 878 300/2019-03
7.4.3
Data backup with the backup function
When the operating computer is connected to the controller, the data backup is performed using
Data
Backup ...
. All of the configuration data and tightening programs in the controller are stored in
the backup file.
It is not possible to display the individual data (e.g. PLC table) in a created backup file, i.e. the backup file
serves as a so-called "collective file". It is only possible to save the data in separate files using
Data
Save tightening cell
.
7.4.4
Automatic data backup with backup/restore function
The automatic data backup with backup/restore function is configured in the
System
Auto Backup/
Restore
menu item.
OK/NOK counter configurations
*.cnt
Auto Backup / Restore configuration
*.cbr
Printer 1/2 configurations
*.dcg
PLC (3964R) 1/2 configurations
*.dcg
FTP configurations
*.dcg
ID code configurations
*.dcg
IPM Protocol configuration
*.dcg
and
*.ipm
PLUS Protocol configuration
*.dcg
and
*.pls
Open Protocol configuration
*.dcg
HTTP Protocol configuration
*.dcg
QDA Protocol configuration
*.dcg
and
*.qda
PFCS-2Port configuration
*.dcg
VW-XML 2.x configuration
*.dcg
Integra-XML configuration
*.cbr
Log book files
*.lbk
Status IPM
*.xml
Status PLUS
*.plu
Nexo configuration
*.nexo
Trace sequence
*.trace
Table 7–10:
Files with file name extensions
Files
File name extension
The
.dcg
files can only be stored or loaded in the respective menu under
System
Tightening cell data
.
More detailed information regarding the data backup can be found in the "Project planning"
documentation of the Rexroth Tightening System 350!
As of version V2.600 of the
Rexroth Tightening System 350
, automatic backup/restore is possible. I.e. all
components must have firmware version 2.600 or higher.
For using the automatic backup/restore function, a CF350 (memory card) has to be inserted in the
compact system (CS) or the communication unit (KE) and the control unit (SE). Otherwise, an error (error
class 3) is returned at the components without CF350.
For systems using data output that applies this CF350 as buffer, the 1 GByte CF350 is recommended.
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...