562
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
IMpdp
You can make the following settings in the
Set Profibus DP interface
group:
No settings can be made in the
Configured ranges
field: The grayed out fields cannot be edited. The
parameters displayed in this field depend on the selected number of I/O points.
A participant profile in form of a GDS file (Generic Station Description - master data file) is required for
commissioning of the IMpdp interface module. The GSD file (
*.
gsd
) allows the software to recognize the
adjustable parameters and their value ranges.
After setting all parameters, create the master data file by clicking
Create GSD file
.
Save the file and
import it into the field bus configurator.
Click
Accept
to take over this data in the configuration for the tightening channel in the BS350.
Table 7–16:
Settings in BS350 for IMpdp - Setting the Profibus DP interface
Element
Description
Station address
Address of the IMpdp in the PROFIBUS network. The address is assigned during
field bus planning. The address section is from 2 to 123. The field bus master
(partner controller) is usually assigned the address 0 or 1.
Number of I points
Number of control signals to be processed via the PROFIBUS interface. Value
range 16 to 64 input signals (2 to 8 bytes)
Number of O points
Number of control signals to be processed via the PROFIBUS interface. Value
range 16 to 64 output signals (2 to 8 bytes)
Receive data
Memory location for receiving the ID code, max. 64 bytes
Send data
Memory location for sending results, max. 198 bytes at 2 bytes for O points
Receive IL data
Memory location for receiving IL data, max. 198 bytes at 2 bytes for I points
These data are processed using the IL function block ControlFieldbus.
Send IL data
Memory location for sending of IL data, max. 198 bytes at 2 bytes for O points
These data are processed using the IL function block ControlFieldbus.
Example
If 16I was selected as the number of I points and 32O as the number of O points, 16 inputs (= 2 bytes)
and 32 outputs (= 4 bytes) will also be available in the field bus configurator.
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...