572
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
IMenip2
IMenip2 is supported as of version V2.600 of the
Rexroth Tightening System 350
.
This parameter dialog consists of two index cards that can be selected in the
Setup EtherNet/IP
interface
group:
•
I/O and data
•
Configuration
Index card: I/O and data
No settings can be made in the
Configured ranges
field: The grayed out fields cannot be edited. The
parameters displayed in this field depend on the selected number of I/O points.
Index card: Configuration
You can select configuration either via DHCP = Dynamic Host Configuration Protocol or via specification
of the IP address with subnet mask and gateway.
Create ESD file button
A participant profile in form of an EDS (electronic data sheet) file is required to commission the IMenip2
interface module. The EDS file (
*.
eds
) enables recognition of variable parameters and their value ranges
in the project planning software.
After setting all parameters, create the EDS file by clicking
Create EDS file
.
Click
Accept
to transfer the data to the configuration for the tightening channel in the BS350.
Table 7–21:
Settings in BS350 for IMenip2 - I/O and data
Element
Description
Number of I points
Number of control signals to be processed via the EtherNet/IP interface: Value
range 16 to 64 input signals (2 to 8 bytes)
Number of O points
Number of control signals to be processed via the EtherNet/IP interface: Value
range 16 to 64 output signals (2 to 8 bytes)
Receive data
Memory location for receiving the ID code, max. 64 bytes
Send data
Memory location for sending results, max. 254 bytes at 2 bytes for O points
Receive IL data
Memory location for receiving IL data, max. 254 bytes at 2 bytes for I points
These data are processed using the IL function block ControlFieldbus.
Send IL data
Memory location for sending of IL data, max. 254 bytes at 2 bytes for O points
These data are processed using the IL function block ControlFieldbus.
The IP parameters (
IP address
,
Subnet mask
and
Gateway
) under
System test
Field bus status
and in the channel or KE configuration at IMenip2 always correspond to the currently applied value. If the
network connection is lost, e.g. if the Ethernet line is disconnected at the interface module, these values
are invalid or 0.0.0.0.
Example
If 16I was selected as the number of I points and 32O as the number of O points, 16 inputs (= 2 bytes)
and 32 outputs (= 4 bytes) will also be available in the field bus configurator.
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...