586
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
7.6.2
Online configuration of the KE
In the online configuration, slots equipped with an IM are highlighted in red in the configuration window;
the inserted IM is referred to in the Notes field by
IMxxx module is new!
The parameters still have to be
set.
7.6.2.1
Loading the KE configuration
The PC and KE must be connected before the online configuration can be loaded (see
).
Below is a description of the configuration and parameter assignment of the KE with the following
components:
•
KE350
•
IM in the slots A, B1, and B2
Use
System
KE configuration
to load the current KE configuration.
The configuration window displays the following (see Figure
):
•
KE with part no., firmware version, and NTP status
1)
•
The permanently installed X7E1 interface with:
– IP address
– Subnet mask
– Host name
– DNS
– Domain name
– Gateway
•
The permanently installed X3C1 interface with:
– Interface type (RS232)
– Baud rate, data bits, stop bits
– Parity
– Protocol
•
the IM to be parameterized in A, B1, and B2
1) NTP = Network Time Protocol. Using the NTP server, the KE time can be set at regular intervals. For
this, the tightening system must be connected to a network via Ethernet. More information on Ethernet
connection and time synchronization using the NTP server can be found in the "Project planning"
documentation of the Rexroth Tightening System 350.
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...