7.6.2.2
Setting up installed interfaces
Ethernet interface X7E1
The installed Ethernet interface is used for tightening results output and for programming the tightening
controller.
The associated parameter dialog is opened by double clicking the parameter field in line X7E1 (see Figure
Fig. 7–29:
Parameter dialog X7E1
You can make the following settings in the
Ethernet interface setup
group:
•
IP address
: Assigned by the network administrator; identifies the participant in the data exchange.
•
Subnet mask
: Assigned by the network administrator; contains information on the network
configuration (address range).
•
Host name:
Name by which the Ethernet participant (here the compact system (CS)) can be
addressed.
•
DNS:
Assignment of logical participant names to unique IP addresses.
•
Domain name
: The domain name is the same for all the participants in an Ethernet, the full logical
name of a participant is
Hostname@Domainname
.
•
Gateway
: Establishes the external connection.
Click
Accept
to store these data in the program.
X3C1 interface
The X3C1 serial interface is designed to connect data collection devices, barcode readers, etc., or as
output interfaces for tightening results data. Open the associated parameter dialog by double clicking one
of the fields in line X3C1 (see Figure
Detailed information on the data exchange via Ethernet can be found under
!
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...