604
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
7.6.4
Configuring the tightening channels
To configure the tightening channels, select
System
Tightening channel configuration
and then
select a tightening channel.
If the tightening channels all have the same configuration, only one tightening channel has to be
configured. The configuration can then be sent to all tightening channels involved in the tightening
application or stored as a file on the PC (see
Tightening channel configuration of the control unit in single-channel operation
The control unit controls and monitors the tightening process of up to two independent tightening
channels per control unit. If you want to operate the control unit in single-channel operation, proceed as
follows:
1.
Open the tightening channel configuration.
– Online configuration:
System
Tightening channel configuration
– Offline configuration:
File
New
Tightening channel configuration
2.
Change the
Operating mode
of the first tightening channel from
2 channels
(default) to
1 channel
.
The
Operating mode
option is not displayed for the second tightening channel.
The control unit is configured for the single-channel operation.
7.6.4.1
Configuration of servo amplifiers with transducer function
Depending on the code, servo amplifiers can be configured to serve as primary transducers or redundant
transducers.
Depending on the servo amplifier selected, the following transducer functions can be implemented:
•
With the servo amplifiers LTE350D and LTU350/1 only "
Redundancy
" is possible.
•
For the servo amplifiers LTS350D, LT353, LT354 and LT355 "
Redundancy
" is preset.
Primary
" is
possible.
•
With the servo amplifier LTU350/1S neither "
Primary
" nor "
Redundancy
" is possible.
If after its delivery, the control unit is operated
directly next to a KE for the first time
, the following
scenario occurs: the control unit is automatically converted to single-channel operation.
As a consequence of non-compliance with the following information an error may occur and both, the
tightening channel and the entire tightening controller may be disturbed.
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...