3 608 878 300
Tightening Technology |
Bosch Rexroth AG 613
System 350
| 3 608 878 300/2019-03
7.7.2
Modular system
The following describes the special features for commissioning a tightening channel that consists of
individual components (LTU350/1, LTS350D/LTE350D, SE, VM) and an ErgoSpin.
7.7.2.1
Interfaces and displays on the LTU350/1 servo amplifier
The following interfaces and displays are integrated in the LTU350/1:
Fig. 7–36:
Interfaces and displays on the LTU350/1
LC display
The LC display allows for displaying the result values (torque, angle, gradient, time) and error codes. Texts
are shown in 4 lines, each with 8 characters. The display is permanently backlit. For more information on
the LC display, see .
LED displays
Three LEDs are located on the front plate of the servo amplifier and provide information on the following
operating states:
Reset button
Press this button to reset the servo amplifier.
XDS1
The ErgoSpin connection cable is connected to the XDS1 interface.
LC display
LED displays
Reset button
ErgoSpin connection at the XDS1 interface
Table 7–35: LED display on the LTU350/1
LED display
BTB
Green
Red
Ready for operation
System error
MS
Green
Red
Ready for operation
Motor contactor error
FG
Green
Off
Servo amplifier release
No servo amplifier release
Reset button
Reset
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...