614
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
7.7.2.2
Interfaces and displays on the LTS350D/LTE350D servo amplifier
The following interfaces and displays are integrated in the LTS350D/LTE350D:
Fig. 7–37:
Interfaces and displays on the LTS350D/LTE350D
LC display
The LC display allows for displaying the result values (torque, angle, gradient, time) and error codes. Texts
are shown in 4 lines, each with 8 characters. The display is permanently backlit. More information on the
LC display can be found in the "Project planning" documentation of the Rexroth Tightening System 350.
LED displays
Three LEDs are located on the front plate of the servo amplifier and provide information on the following
operating states:
Reset button
Press this button to reset the servo amplifier.
XDS1
The ErgoSpin connection cable is connected to the XDS1 interface.
LED displays
Reset button
LTE350D: XDS1 interface for hand-
held nutrunner ErgoSpin
LC display
LTS350D: XDS2 interface for
tightening spindle
XDN3 interface for interrupting the
motor release
Table 7–36: LED display on the LTE350D
LED display
BTB
Off
Green
Green,
flashing
No power supply or LTS/LTE is in download mode
Ready for operation
Not ready for operation, but no system error; emergency OFF has been
triggered
FG
Green
Off
Servo amplifier release
No servo amplifier release
Error LED
Red
System error
Reset button
Reset
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...