618
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
If such tightening channel configuration has been sent to the tightening controller, the BS350 outputs the
following message:
The values stored on the hand-held nutrunner (MFU factor, ident number, comment, test intervals,
output drive data) are not overwritten by sending.
Proceed as follows in order to change tightening channel configurations containing an ErgoSpin hand-
held nutrunner of type VarioLine (ESV) or of type pistol grip nutrunner (ESM):
1.
Load the tightening channel configuration from the tightening controller.
– Compact system: see
„Loading the tightening channel configuration“
– Modular system: see
„Loading the KE configuration“
.
2.
Adjust the tightening channel configuration.
– Compact system: see
„Completing the tightening channel configuration“
– Modular system: see
„Configuring the tightening channels“
.
3.
Send the changed tightening channel configuration to the tightening controller, see
The tightening channel configuration on the tightening controller has been changed.
7.7.3.1
Storing the tightening programs
The ErgoSpin hand-held nutrunners are supplied from the factory without tightening programs.
Proceed as follows for initial commissioning:
1.
Create the tightening programs in the operating system BS350.
2.
Send the created tightening programs to the control unit.
ErgoSpin with stored tightening programs
For initial commissioning of an ErgoSpin hand-held nutrunner on which tightening programs have already
been stored at the factory, proceed as follows:
Activate the additional functionality
Use tightening programs from hand-held nutrunner
(program 99 and 0..3)
(see
).
In order to allow for tightenings, send the configuration to the control unit.
The tightening programs on ErgoSpin hand-held nutrunners supplied from the factory can be deleted.
If deviating tightening programs (0 to 3, 99) are already on the tightening controller, they will be
overwritten after acknowledgement of error message code 382, if the additional function
Use tightening
programs from hand-held nutrunner (program 99 and 0 to 3) (
see
) is
activated.
NOTICE
Loss of data
Tightening programs can be deleted in the hand-held nutrunner, if the tightening programs in the SE
need to be deleted with
Data
Delete SE/CS ...
.
Before deleting, deactivate the additional function
Use tightening programs from hand-held
nutrunner (program 99 and 0...3)
and send it to the tightening channel.
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...