3 608 878 300
Tightening Technology |
Bosch Rexroth AG
91
System 350
| 3 608 878 300/2019-03
Temperature specifications
The following temperature limit values apply when using the system components:
The controller components, including compact system, servo amplifiers, measurement transducers, as
well as ErgoSpin hand-held nutrunners are equipped with temperature sensors for protection against
overheating.
The limit temperatures, which trigger an error in the system if they are exceeded, can differ. They depend
on the module (controller, measurement transducer, etc.) and the installation location of the sensors
within the module (see table
For diagnosis purposes, the BS350 operating system provides an overview of the current system status
under
System test
Tightening cell info
Temperature
. This overview is an aid for evaluating the
temperature conditions in the system. Using this and the limit temperatures from Table
, it is possible
to assess whether there are sufficient reserves in the system.
Fig. 4–18:
Temperature display
Table 4–19:
Permissible ambient temperatures
System component
Temperature range [
°
C
]
Compact system
0
–
45
System box
0
–
45
Card rack field
0
–
60
ErgoSpin
0
–
40
Tightening spindle
0
–
55
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...