92
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
The system should basically be considered intrinsically safe: If the system detects an overtemperature
fault, it will report a system error and remain blocked until it is in the permissible temperature range again.
4.3.1.3
Motor-breaker
4.3.1.4
Busbar system for power supply
The busbar system has several disadvantages:
•
The impedance of the supply cable is decisively influenced by the length of the busbar. For example,
busbars with a length of 50 m provide a supply cable over 50 m.
•
The length of the supply cable to the busbar inside the building must be taken into consideration.
Particularly if the supply cable is only connected to the busbar on one side, the impedance is defined
by the length of the busbar and the supply cable.
•
As the attachments are flexible, potential equalization may not be available on site.
•
Interferences affecting the tightening system, e.g. via the spindle line, cannot be dispersed due to the
high impedance of the protective conductor and the mains lines. They may lead to interferences in
the electronic system.
•
Connection via the rollers to the steel beam system is not possible as the rollers often consist of
plastic.
Table 4–20: Temperature limits at the temperature sensors
Limit temperature Error
Error
class
CS
72
°
C Error
1010
"Temperature warning level" – Temperature warning level reached
3
75
°
C Error
1011
"Temperature error" – Permissible temperature exceeded
4
SE/KE
72
°
C
Error 1010/2010
"Temperature warning level" – Temperature warning level reached
3
75
°
C
Error 1011/2011
"Temperature error" – Permissible temperature exceeded
4
Servo amplifier
80
°
C
Error 101
"LT temperature error" – Maximum permissible temperature on heat sink exceeded
4
Measurement transducer, offset drive with integrated transducer
65
°
C
Error 101
"LT temperature error" – Maximum permissible temperature on heat sink exceeded
4
EC motor
130
°
C
Error 102
"Motor temperature error" – Maximum permissible coil temperature exceeded
4
ErgoSpin
65
°
C
Error 203/223
"MSEN1/2: Temperature error" – Permissible temperature exceeded
4
CAUTION
Risk of damage to persons and property!
Dangerous shock currents due to insufficient PE wire connections!
Protective conductor connections may not be affected by mechanical, chemical, or
electrochemical influences. The connection must be permanent.
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...