3 608 878 300
Tightening Technology |
Bosch Rexroth AG
97
System 350
| 3 608 878 300/2019-03
Fig. 4–25:
Shutdown via mains lead
* The external power pack at this interface is connected in parallel to the internal 24V power supply. The
internal isolating diode ensures that with equally high supply voltages (internal = external), the internal
power supply bears the load. The power pack must be stabilized and protected against short circuits and
overloads. Maximum ripple voltage 240 mV
pp
, 150 mV
RMS
.
More boundary conditions for emergency stop on the user side:
•
When an emergency OFF is triggered (mains supply interrupted), the external 24V supply must not
be switched off as otherwise data may be lost.
•
The external 24V supply may not be generally switched in order to avoid high starting currents (on
the secondary side).
•
When an emergency OFF is triggered (mains supply interrupted), no CW/CCW should be set, as
this can lead to system errors.
•
The maximum line length between power pack and VM350 must not exceed 5 m.
•
Triggering the emergency OFF (mains switching) is subject to the same time intervals as switching
on the mains. After the return of the mains power supply, wait approx. 10 s before setting CW/ CCW.
XDN2
=
24 V
0 V
X1S2
- Kx
- Ky
3
3
1
2
1
2
3
4
3
4
5
6
5
6
- X
24 V
21
22
21
22
13
14
24 V
21
22
21
22
- Kx
3
- Ky
4
- Kx
A1
A2
0 V
- Ky
A1
A2
1
2.5
3
4.5
5
0.5
21
22.1
1
2.6
3
4.6
5
0.6
21
22.2
Reset
LTU350/1
Reset
LTU350/1
Reset
EXIT
INT
XDN2
X1S1
VM350
X1S2
Power pack in accordance with EN50178*
Emergency-OFF
CONTROLLER
ON
EMERGENCY OFF RELAY
EX. PNOZ MUSHROOM
Terminals
-XL x and -XL y
must be mounted next
to the corresponding
contractors
SAMPLE CIRCUIT DIAGRAM
Motor-breaker
Shutdown is effected via
the mains lead and must be
realized by the customer.
The user must ensure that the boundary conditions for emergency stop according to EN ISO 13849 are
satisfied.
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...