3 608 878 300
Tightening Technology |
Bosch Rexroth AG 143
System 350
| 3 608 878 300/2019-03
CS ILOut
Compact System Indra Logic Out Bit 0-7: IL-specific output signal
Output signal used for:
•
Tightening channel (
CS ILOut x.0-7
)
IL-specific signals are provided for special adjustments to customer requirements. They are, e.g., suitable
for looping through signals: a signal can be read by the controller via interface modules and then output
to the partner controller using the controller.
CyCmp
Cycle Complete: Process end
Output signal used for:
•
Tightening channel (
CyCmp
)
•
Communication unit in single-channel operation (
CH x.y CyCmp
)
•
Communication unit in application operation (
FO x CyCmp
)
CyCmp
= "high" signals the end of a tightening operation (sequence and results processing). The
tightening channel is ready for the next tightening.
•
CyCmp
for single-channel tightenings (as of version V2.200)
As of V2.200, the results output is no longer uncoupled from the CyCmp signal. This means the
controller has internally processed its data before the CyCmp signal is set.
The completion of the results output depends on the used data output protocols. Some protocols
work asynchronously. This means the data is buffered on the data carrier and the actual transmission
takes place outside of the CyCmp (see table below).
•
CyCmp
in an application
If the tightening channel was started with an application, the results data will be transferred to the KE
before process end. It will be output by the KE via the data interface as a part of the results output
for the application.
Depending on the used data protocol, the results output of the application is completed when the
FO x CyCmp
KE signal is "high" (see table below).
DisableAck
Disable acknowledge: Acknowledges that an application block is disabled
This signal is available as of version V2.300 of the
Rexroth Tightening System 350
.
Output signal used for:
•
Communication unit in application operation (
FO x DisableAck
)
The
OK
and
NOK
signals that are relevant for tightening are available with the
CyCmp
sequence end,
irrespective of intermediate buffering of the related result data records.
synchronous asynchronous
Printer output
x
PLC
x
FTP synchronous
x
FTP asynchronous
x
Field bus data
x
IPM
x
XML
x
PLUS
x
OpenProtocol
x
IL data element
x
Details on data output and its chronological order can be found in the individual chapters of
.
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...