3 608 878 300
Tightening Technology |
Bosch Rexroth AG 225
System 350
| 3 608 878 300/2019-03
6.2.3
Formats of the results output
To set the desired output format:
1.
In the BS350 operating system, click
System
Tightening cell data.
2.
Click
FTP
.
3.
Select the
Results
index card.
The index card is divided as follows:
Fig. 6–15:
Configuration of formats of the results output (FTP)
6.2.3.1
Transfer settings
In the Transfer menu, it is determined how the results output will be processed in the tightening process.
The following settings are possible:
•
•
Before process end
•
•
Timeout
: The value set here defines how long (in seconds) the FTP client should try to establish a
connection to the server (
FTPHookup
) before the signals are generated and a corresponding entry
is made in the error list. The signals generated are:
FtpF
= 1 and
NF
= 0 (with compact system) or
KE FtpF
= 1 and
KE NF
= 0 (with modular system). As long as the signal
NF
= 0 (with CS351) or
KE NF
= 0 (with KE350) is set, the tightening system is not ready to perform other tightening
processes (a list of the corresponding system errors can be found
).
FtpF
= 1 /
KE FtpF
= 1 and
NF
/
KE NF
are reset via the
ResF
and
KE ResF
signals, respectively.
1
Transfer settings
2
Results selection
3
Output formats
1
2
3
With the setting "Before process end", the tightening results data are lost if it is not possible to transfer
via Ethernet.
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...