3 608 878 300
Tightening Technology |
Bosch Rexroth AG 391
System 350
| 3 608 878 300/2019-03
MID 0065 revision 001
Table 6–104:
MID 0065 revision 001
Parameter
Comments
Bytes
Tightening ID
With an activated OP, consecutive number for each tightening result.
The value consists of ten ASCII characters.
ID
01
2
Value range
0000000000 – 9999999999
Presetting
-
Example:
Tightening ID
123456
Value
0000123456
10
ID code
Contains the first 25 bytes of the ID code.
The value consists of 25 ASCII characters.
ID
02
2
Value range
0x20 – 0x7F
Presetting
-
Example:
ID code
123456
Value
123456
25
Tightening program number
Number of the current tightening program.
The value consists of three ASCII characters.
ID
03
2
Value range
000 – 999
Presetting
-
Example:
Tightening
program number
5
Value
005
3
OK counter value
– Start as a single channel (SE/CS): Actual value of the OK counter
– KE application start: Default value is 0
– Rexroth OP/Rexroth OP-BMW: Exception if
MID61/MID65
evaluation and batch information from application result
is
selected in the configuration for Open Protocol: If the application is
parameterized from the job with a counter, the actual value of the OK
counter is returned.
The value consists of four ASCII characters.
ID
04
2
Value range
0000 – 9999
Presetting
– For a single channel: -
– If starting in an application: Fixed value 0001
Example:
OK counter value
4
Value
0004
4
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...