3 608 878 300
Tightening Technology |
Bosch Rexroth AG 431
System 350
| 3 608 878 300/2019-03
6.7.7.20
Keep alive messages
MID 9999
Keep alive message
Sent by:
superordinate computer
The superior computer sends a keep alive message to the tightening controller. The tightening controller returns the
received message to the superior computer.
A communication timeout of 15 s (can be parameterized by the BS) applies to the tightening controller, i. e. if no
message is exchanged between the superior computer and the tightening controller within 15 s, the tightening
controller will believe that the connection has been disrupted and disconnect it.
Note:
We recommend sending a message (keep alive or other) to the tightening controller at the latest every 10 seconds
to avoid undesired connection disruptions (with high latency times with TCP/IP).
Revision:
001
(supported by Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW)
Data field:
is empty, 0 bytes
Possible response
MID
Error no. Comment
Keep alive message MID 9999 (mirrored
from the tightening controller)
–
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...