436
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
6.8.1.1
Diagnosis and troubleshooting
For diagnosis, the following two options are available:
•
Detailed text protocol
This protocol can be accessed via BS350 under
System test
Diagnosis
HTTP
.
•
Sequence trace
The sequence trace can be accessed via BS350 under
System test
...
FF3
or
FF4
.
•
BS350 error list for system errors
•
Via BS350, under
System test
EtherNet...
, the counter values of the HTTP diagnostic counter
can be checked on the
HTTP diagnostic counter
index card.
6.8.2
Parameter of results output
The output file includes various parameters:
•
General tightening result parameters
•
Step data: In the results file, all tightening steps of the program are put out individually.
•
Step result parameters
•
Tightening function parameters
: All target and monitoring functions relating to the
step, including designation, target value and actual value are put out.
•
: In addition, the associated graph points are returned
under each step:
•
Tightening application parameters
Graph data coded as base64
Activate the option for transmission of graph points coded in Base64. Otherwise,
the graph points are transmitted as text.
Graph data
Activate the option for transmission of measuring points (angle, torque, gradient,
redundancy torque, redundancy angle, time). Otherwise, no measuring points are
transmitted.
Error transmission
Activate the option for transmission including errors. Otherwise, no errors are
transmitted.
Settings
The BS350 operating system provides the option of printing (
Print…
), storing
(
Save as…
) settings for HTTP or loading (
Open…
) saved settings.
Protocol
– Activated
Enable the check box to activate data output via HTTP.
If results output is disabled, no more results files will be generated. Results files
which have already been generated and still exist will not be output before HTTP
output has been reactivated.
– Load default values
Click this button to reset the data changes to standard values.
– Convert
Click this button to start the conversion.
– OK
Click this button to save the data changes.
– Cancel
Click this button to close the dialog window without accepting the changes.
Table 6–126:
Settings in BS350 for HTTP
Element
Description
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...