The type number is applied by the tightening system with rising edge of InPos. The number must be stable
until AckInPos acknowledgement. The type number is used to select a configuration stored in the
tightening system (assignment of tightening results to QIs):
The VarIdent codes are applied by the tightening system with rising edge of InPos. The data must be
stable until AckInPos acknowledgement.
Profinet interface - Tightening system outputs (PLC inputs)
The following block describes general signals of the tightening cell (see table
The following PLUS communication signals are also included:
•
ReportOK: This signal is set by the tightening controller after successful results data transmission to
PLUS.
•
ReportNOK: This signal is set by the tightening controller if an error occurred during results data
transmission to PLUS.
•
AckReportStart: This signal is set by the tightening controller as acknowledgement for the
StartReport signal of the PLC (see above).
•
AckInPos: This signal is set by the tightening controller as acknowledgement for the InPos signal of
the PLC (see above).
•
AckTypOk: This signal is valid with the rising edge of AckInPos and indicates that the ID codes and
type information of the PLC have been successfully accepted and decoded by the tightening
controller.
•
ChnErr: New channel system error is ready for application by the PLC (see below, signals
Ch_ErrCode/Ch_ChnNum/Ch_ErrClass).
Table 6–169:
Varident: Addresses 64-87
Signal
Data type
Address
Signal name/description
A-PartNo
Array [0..9] of Char
%64
A part number
LineNo
Array [0..1] of Char
%74
Line number
Date
Array [0..5] of Char
%76
Date (YYMMDD)
Time
Array [0..5] of Char
%82
Time (hhmmss)
Table 6–170:
General bit signals of the tightening cell/PLUS: Addresses 0-1
Signal
Data type
Address
Signal name/description
KE_Rdy
Bool
%Q0.0
KE ready
FC_Rdy
Bool
%Q0.1
Tightening cell ready
KE_NF
Bool
%Q0.2
Communication unit no fault
FC_NF
Bool
%Q0.3
Tightening cell no fault
FC_BypsAc
Bool
%Q0.4
At least one spindle is set to bypass mode
ReportOK
Bool
%Q0.5
Report OK
ReportNOK
Bool
%Q0.6
Report NOK
AckReportStart
Bool
%Q0.7
Acknowledge start report
AckInPos
Bool
%Q1.0
Acknowledge in position
AckTypOk
Bool
%Q1.1
Acknowledge for TypeNo OK
ChnErr
Bool
%Q1.2
New channel error active
R_SRS_A12
Bool
%Q1.3
Reserve
R_SRS_A13
Bool
%Q1.4
Reserve
R_SRS_A14
Bool
%Q1.5
Reserve
R_SRS_A15
Bool
%Q1.6
Reserve
R_SRS_A16
Bool
%Q1.7
Reserve
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...