580
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
7.5.4.3
Sending/saving data
Tightening programs have to be sent to the tightening controller before they can be used. They can also
be stored as files on the PC (see
7.5.5
Configuration SE/CS PLC assignment table
The PLC assignment table defines the assignment of the control signals to the tightening controller's
physical interfaces. The tightening controller can be integrated into a system sequence with these control
signals. The following number of inputs and outputs are available on the interfaces:
A maximum of 256 input and output signals can be used.
With automatic channel configuration, the PLC assignment table is created in accordance with the
presettings when the compact system is commissioned with the ErgoSpin. It can be loaded from the
compact system by selecting
System
SE/CS PLC assignment table
.
Send the preset PLC assignment table to the tightening controller; it can also be stored as a file on the
PC (see
Table 7–24:
Number of inputs and outputs
System component
Number of inputs/outputs SE
Number of inputs/outputs CS
ErgoSpin
4/0
4/0
IMpdp
–
16 to 64/16 to 64
IMdev
–
16 to 64/16 to 64
IMpnio, IMpnio2
–
0 to 64/0 to 64
IMenip, IMenip2
–
16 to 64/16 to 64
IMmtcp
–
16 to 64/16 to 64
IMecat
–
16 to 64/16 to 64
IM24V
5/6
10/13
HMI
–
8/0
HVO
–
8/8
IL
–
32/32
OP
–
33/24
XML
–
22/25
Information on the configuration of the PLC assignment table can be found in section
The detailed description of the control signals can be found in chapter
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...