Fig.9-15:
Dialog for image update
This tab is used for loading an image file into the IndraControl VCH 08.1. The
operating system can be updated via a newly integrated image file.
The image file may be copied into any diretory, but "not" into the
\FlashDr directory.
Do execute a "Check File" befor an image update. The image file
can be filed for example in the "tmp" directory.
Image File
A new WinCE image file can selected in the file selection dialog.
If an image update is performed, the registry will be deleted auto‐
matically and the IndraControl VCH 08.1 will reboot. Then the
IndraControl VCH 08.1 starts with the factory settings and all set‐
tings have to be saved newly (touchscreen, joystick, override po‐
tentiometer, control panel, etc.).
Check File
The selected file can be checked for validity. "Check File" is only active if a valid
image file has been selected.
Start Update
Click on "Start Update" to start the update and to display the progress. "Start
Update" is only active if a valid image file has been checked successfully for
validity by "Check File".
Clear Registry
If this option is selected, the registry is deleted and the IndraControl VCH
08.1 is rebooted automatically. Then the IndraControl VCH 08.1 starts with the
factory settings and all settings have to be saved newly (touchscreen, joystick,
override potentiometer, control panel, etc.).
Version Information
The "Version" tab is contained in the "Config Tool", see
figuration Tool (Config Tool)" on page 100
DOK-SUPPL*-VCH*08.1***-PR02-EN-P
Rexroth IndraControl VCH 08.1 Hand-held Terminal
Bosch Rexroth AG
103/117
Software