Material
Front panel: Aluminum, metal cover: V2A
Degree of protection
Front panel IP 65,
Rear panel IP 30
Fig.4-7:
Technical data of the IndraControl VAC 30.2
4.7
Ambient Conditions
In operation
Storage
Transport
Max. surrounding air
temperature
+0 ℃ to 50 ℃
-20 ℃ to +70 ℃
-20 ℃ to +70 ℃
Relative humidity
5 % to 95%
5 % to 95 %
5 % to 95%
Air pressure
Up to 2000 m above
sea level acc. to
EN 61131-2
Up to 3,000 m above
sea level acc. to
EN 61131-2
Up to 3,000 m above
sea level acc. to
EN 61131-2
Mechanical strength Max. vibration:
10 Hz ≤ f < 57 Hz
with 0.15 mm
9 Hz ≤ f < 150 Hz
with 2 g
Max. shock:
25 g/11 ms (IEC
60068-2-27)
Max. shock:
25 g/11 ms (IEC
60068-2-27)
Fig.4-8:
Ambient conditions of the IndraControl VCH 08.1
4.8
Accessories
Wall holder
For stationary operation or for storage
VAS 01.1
Wall holder with cable holder
Connecting cable
Torsional, bending and impact strength with ready-
made 17-pin round connector
VAS 05.1
8 m
RKS0011/16,0
RKS0012/016,0
16 m extension cable for devices with stop button
16 m extension cable for devices with emergency stop
button
Fig.4-9:
Accessories for IndraControl VCH 08.1
Ordering information for the accessories is listed in
.
4.9
Coding
Identify the device with the name plate on the rear side of the device.
Bosch Rexroth AG
DOK-SUPPL*-VCH*08.1***-PR02-EN-P
Rexroth IndraControl VCH 08.1 Hand-held Terminal
30/117
Technical Data