7.4.4
X2.1: STOP Button
Pin assignment
Pin
Signal name
X2.1 pin1
STOP pushbutton 1 IN
X2.1 pin2
STOP pushbutton 1 OUT
X2.1 pin3
STOP pushbutton 2 IN
X2.1 pin4
STOP pushbutton 2 OUT
Fig.7-19:
Pin assignment of the STOP pushbutton X2.1
Risk of injury due to malfunction of the stop
button or emergency stop button.
DANGER
The circuit of the stop button or emergency stop button might be operated with
a maximum of 30 V and must be protected with a 2-A-fusible cut-out.
7.4.5
X2.1: Emergency Stop Button
Pin assignment
Pin
Signal name
X2.1 pin1
Emergency stop button 1 IN
X2.1 pin2
Emergency stop button 1 OUT
X2.1 pin3
Emergency stop button 2 IN
X2.1 pin4
Emergency stop button 2 OUT
Fig.7-20:
Pin assignment of the X2.1 emergency stop button
Risk of injury due to malfunction of the stop
button or emergency stop button.
DANGER
The circuit of the stop button or emergency stop button might be operated with
a maximum of 30 V and must be protected with a 2-A-fusible cut-out.
7.4.6
X2.2: Enabling Button
Pin assignment
Pin
Signal name
X2.2 pin1
Enabling button 1 IN
X2.2 pin2
Enabling button 1 OUT
X2.2 pin3
Enabling button 2 IN
X2.2 pin4
Enabling button 2 OUT
Fig.7-21:
Enabling button X2.2
Risk of injury due to malfunction of the enabling
button.
DANGER
The circuit of the enabling device might be operated with a maximum of 30 V
and has to be protected with a 2-A-fusible cut-out.
Bosch Rexroth AG
DOK-SUPPL*-VCH*08.1***-PR02-EN-P
Rexroth IndraControl VCH 08.1 Hand-held Terminal
82/117
Pin Assignments of the IndraControl VCH 08.1