10.4 Mounting dimensions of the built-in devices
1
A
B
①
Mounting cut-out
Fig. 10-8: Mounting dimensions
Operator display
Dimension A
Dimension B
VEP 15.6
403
255
VEP 21.6
535
330
Tab. 10-2: Dimensions of the mounting cut-out in mm
10.5 Demounting the built-in devices
1. Disconnect the operator display.
2. Remove all connected cables.
3. Loosen the screws of the clamp fastenings.
4. Fold in the clamp fastenings.
5. Press the latching lug of the installation aid.
Fig. 10-9: Latching lug
6. Remove the operator display from the mounting frame.
VEP 15.6 Multi Touch, VEP 21.6 Multi
Touch
Bosch Rexroth AG
Mounting, demounting and electric installation
DOK-SUPPL*-VEPXX.6MTHU-IT02-EN-P
31/53