Installing the VSPD 2
Pin
Description
Type
2 MA+ Solenoid
a
+
4 MA- Solenoid
a
-
6 MB+ Solenoid
b
+
8 MB
- Solenoid
b
-
10 Shield Shield
12 L1O- n.
c.
14 L1I-
n.
c.
16 L1I+
n.
c.
18 L1O+ n.
c.
20 Ground System
ground
22
DO 3
Discrete output
24
DO 4
Discrete output
26
DO 5
Discrete output
28
DO 6
Discrete output
30 U
B
Supply
voltage
32 LO
Supply
GND
Tab. 3 Pin assignment row z
Single-solenoid valves are to be connected to solenoid A+/A-. The sole-
noid B+/B- connection then remains open. For single-solenoid valves,
only positive command values are recognized as being valid.
Row z