Company Registered in England No: 4167649 VAT Registration No: 732 5692 25 BS EN ISO 9001:2008 No: LRQ 0964389
+44 (0)1204 699 959
enquiries@hyquip.co.uk
Hyquip Limited New Brunswick Street Horwich Bolton Lancashire BL6 7JB UK
www.hyquip.co.uk
/web/index
28/
48
Bosch Rexroth AG |
Hydraulics
Installation and operation | RE 30523-B/09.13
4 Operating the VSPD
Fig. 11 Menu tree „Command Adjust. Part 1“
Level 1
Level 2
Level 3
Level 4
Level 5
Command
Adjust.
Press “ENTER + ESC“
Overlap
to go to the configura-
tion menu
Deadband
[0.0~+100.0]
%
Step
+
[0.0~+100.0]
%
Step
-
[0.0~+100.0]
%
Offset
[-100.00~+100.00] %
Limit
Limit
+
[0.0~+100.0]
%
Limit
-
[0.0~+100.0]
%
Current Curve User 1
Precurrent
[0~+3000]
mA
Jump
Current
[0~+3000]
mA
Max.
Current
[0~+3000]
mA
Current Curve User 2
X0
[-100.0~+100.0] %
Y0
[0~+3000]
mA
X1
…
Y1
…
X2
…
Y2
…
X3
…
Y3
…
X4
…
Y4 …
X5
…
Y5
…
X6
…
Y6
…
X7
…
Y7
…