RE 30523-B/09.13 | Installation and operation
Hydraulics
| Bosch Rexroth AG
39/48
Operating the VSPD 4
To show setpoints/feedback values on the display run mode.
In this example, the signal "OUT1"(see Fig. 7 Menu tree „Setup“) will be used.
The card should be in Run Mode.
The display will show scrolling text to display the manufacturer’s name, the software
version for the controller, or a custom configured text string.
¾
Press and hold the “ENTER“ and “ESCAPE” keys for at least 2 seconds until the
display reads “Setup“.
9
The card is now in Configuration Mode.
¾
Press
“ENTER”.
9
The card is at the second level of the Configuration Menu.
¾
Press the “UP” or “DOWN” keys to select “Display”.
¾
Press
“ENTER”.
9
Menu entry "Text" is displayed.
9
Press the “UP” or “DOWN” keys to select "OUT1".
¾
Press
“ENTER”.
9
The signal "OUT1" is displayed when the card returns to Run Mode.