44/104 Bosch Rexroth AG
Hydraulics training system WS290 | RE 00225-B/2.15
Technical data and dimensions
6.1.2
WS290 training system with load-sensing
Table 7:
Technical data for the WS290 training system with load-sensing
Denomination
Unit
Value
Total weight
without oil filling and device kits
*(Varies depending on equipment type)
kg
Approx. 270 to 415 *
Dimensions
Length max.
mm
1810*
* (Varies depending
on the equipment
type)
Width max.
mm
800
Height max.
mm
1950 *
Min. operating temperature
°C
+20
Max. operating temperature
°C
+60
Place of installation
Closed room
Ambient temperature
°C
+10-25
Max. relative air humidity
%
90 at 20 °C
Max. installation height
m
1000 above sea level
Pneumatics
Max. operating pressure
bar
8
Hydraulics
Max. operating pressure
Industrial/Mobile
Hydraulics
bar
50/60
Safety pressure
bar
70
Standby pressure
bar
15
Tank volume
l
40
Oil type (DIN 51524)
HLP VG22
Cleanliness
(ISO 4406)
Class
20/18/15
Flow
l/min
8
Mains connection
Connection/operating
voltage
V
230 / 230
(For D and Europe)
Frequency
Hz
50-60
(For CH)
Nominal power
kW
1.5
Mains connection
Connection/operating
voltage
V
400 / 400
+230 for sockets
(For D and Europe)
Frequency
Hz
50-60
Nominal power
kW
2.2
Fuse
A
16
Protective earthing
PE (zero or
FI circuit breaker)
A-rated continuous sound pressure level
(at the workplace of the operating personnel –
during displacement)
dB (A)
< 57