background image

Installation Instructions for the

RF3224 RF Receiver

1.0  General Information

The RF3224 RF Receiver allows the use of wireless
devices when using the D6412 Control Panel.

2.0

Specifications

3.0

Mounting

3.1

Mounting Considerations

• Whenever possible, mount the receiver centrally to all

wireless sensors.

• Mount the receiver vertically with at least 25 cm

(10 in.) clearance above it for the antennas.

• Avoid mounting the receiver in areas with significant

metal or electrical wiring, such as furnace rooms and
utility rooms. If unavoidable, mount the receiver with
the antennas extending above any metal surface.

• Avoid mounting the receiver in areas where it may be

exposed to moisture.

• Reception distances are generally improved with

higher mounting locations and with no metal objects
near the antennas.

3.2

Wall Tamper Setup

To enable the wall tamper switch, follow the procedure
below. If not using the wall tamper, go to Section 3.3
Mounting the Receiver
.
1. Remove the receiver's outer cover and set it aside (see

Figure 1).

2. Press the latch to remove the inner cover (see Figure 2).

3. Move the wall tamper jumper as shown in Figure 3.

4. Replace the inner cover.
5. Place the spring from the hardware packet over the

shaft of the tamper switch located on the back of the
receiver (see Figure 4).

Note: Gently press the spring onto the tapered shaft. 

Do not

force it down onto the shaft.

3.3

Mounting the Receiver

1. Determine the mounting location of the receiver.
2. If not already done, remove the outer cover from the

receiver and set it aside (see Figure 1).

3. Place the receiver base on the wall at the desired

mounting location and mark the two mounting holes
(see  Figure 5).

4. Drill holes and install anchors (supplied), if necessary.
5. Secure the receiver base to the wall with screws

(supplied).

6. Insert an antenna into the outside terminal on two of

the antenna connectors as shown in Figure 6. Tighten
screws to secure the antennas.

1

Figure 1: Removing the Outer Cover

1 - Insert screwdriver here and press in.

1 - Wall tamper jumper
2 - Wall tamper disabled (default position)
3 - Wall tamper enabled (jumper left on pin for storage only)

  ADDR

R

B

G

Y

1

2

3

Figure 3: Wall Tamper Jumper

Figure 4: Installing the Tamper Spring

1 - Rear of receiver

1

Dimensions
(H x W x D)

10.8 cm x 15.2 cm x 3.1 cm
(4.25 in. x 6.0 in. x 1.2 in.)

Operating
Temperature

0

°

C to +65

°

C (+32

°

F to +150

°

F)

For UL Listed requirements, the temperature
range is 0

°

C to +49

°

C (+32

°

F to +120

°

F)

Frequency

304.00 MHz

Power
Requirements

12 VDC, 30 mA, nominal

Compatible
Control Panels

D6412, D4412, DS7240, and DS7220

Compliance

This device complies with Part 15 of the FCC
Rules and the RSS-210 of Industry and
Science Canada. Operation is subject to:

 

The device not causing harmful
interference, and

 

The device accepting any interference
received, including interference that may
cause undesirable operation.

Changes or modifications not expressly
approved by Bosch Security Systems can void
the user’s authority to operate the equipment.

Table 1: Specifications

  ADDR

R

B

G

Y

2

1

Figure 2: Removing the Inner Cover

1 - Cover tamper
2 - Press latch to remove inner cover.

Reviews: