High Density Video Cassette Recorder |
Instruction Manual
|
Troubleshooting
Bosch Security Systems | 26 Feb 2003 | Draft
EN
| 24
Using the RESET button
(located at the front panel of VCR)
This button should be used to solve the following
symptoms;
•
The power cannot be switched on, even when
power cord is connected to the unit.
•
When the VCR’s display does not display.
•
When the VCR does not operate normally.
•
Use a pencil or ball-pen when you press the
RESET button.
Symptom
Check & Correction
Recordings in of an observation multiplexer
system 18, 30, 48, 72, 120, 168, 240 or
960 mode can not be played back in 6
hour mode (no update of picture)
• Set VEXT OUT on 2 FIELDS in the record mode setup menu.
• For new recordings it will be possible to playback in 6 hour mode.
Alarm recording does not work.
• Is the external switch correctly connected?
Playback speed is fast or slow.
• Is the playback mode set to the desired mode with PB/REC SPEED
button?
During the playback, the picture is waving
intermittently from side to side.
• Please confirm the camera setting to INTERNAL SYNC mode.