Installation Instructions
20
4. Standard key (without security card):
Reading in keys via the reader
Keys (maximum 16) can be read in directly via the reader if the 8-digit identification number
is not entered during programming. In the programming program (e.g. WinPara or NzPara),
select for the keys to be read in via the reader (select the parameter
"standalone"
for SE
220 when using NzPara). The control panel must be programmed before the keys are read
in.
Reading the standard key into the reader replaces the manufacturer's standard works code
with the standard key's code.
Operation sequence:
1.
The plugs with the LSN lines (3.4 and 7.8) must be removed from the control
unit. The control panel will display an LSN line malfunction message.
2. Connect the jumper on the control unit's circuit board to bridge B2.
4. Press and hold the key button and hold the remaining keys up to the circle on the center
of the reader at a maximum distance of 2 cm until you hear a short confirmation signal.
The flashing signals of the control
unit's yellow LED and the red LED
on the reader correspond with
the number of keys.
5. Connect the jumper back to B1.
¨
The yellow LED on the control unit and the red LED on the reader go out. This com-
pletes programming the keys.
6. Reconnect the plugs with the LSN lines to the control unit and reset the LSN line mal-
function message on the control panel.
!
3. Press and hold the key button and hold any standard key up to the
circle on the center of the reader at a maximum distance of 2 cm until
the red LED flashes and you hear two short confirmation signals.
2nd key
1st key
3rd key
etc.