Installation Instructions
24
Starting Up a Lockable Code Keypad
(or changing user codes)
Define your user code during the first start-up. You can change your
user code at a later date. Both operational procedures are identical.
User codes can only be changed if the soldering bridge LF1/LF2
on the keyboard circuit board is closed (see code keypad instal-
lation instructions).
Use this key to verify entries.
Use this key to abort an operation.
Define user code
or
change user code
(when the system is disarmed) as follows:
1. Press the
"+"
and
"-"
keys simultaneously for 3 seconds.
¨
The reader's buzzer will sound for 1 second and the red and green LEDs will flash.
2. Press and hold the key button and hold the SmartKey up to the reader for > 1 second. This
will assign the SmartKey to the corresponding
user number (ID)
. Users without a key must
enter their
user number (ID)
.
¨
The buzzer will sound for 1 second and the LEDs will be deactivated.
3. When starting up for the first time, enter
"000000"
and confirm your input with the
" - "
key
.
- or,
If you want to change the user code, enter the "old user code" and confirm your input
with the " - "
key.
¨
The reader's buzzer will sound for 1 second and the green LED will light up.
4. Enter the new user code and confirm your input with the
“ - “
key.
¨
The reader's buzzer will sound for 1 second, the green LED will light up and the red LED
will flash.
5. Enter the new user code once again and confirm your input with the
" - "
key.
¨
The reader's buzzer will sound for 3 seconds, and the green and red LEDs will light up for
3 seconds and then go out.
¨
The new user code is now valid.
-
0
+
3
2
1
6
5
4
9
8
7
!
The user code for the NZ 300 LSN and "integrated" SmartKey is described in de-
tail in the NzPara online help under "User Codes" (different default setting).
!