Technical Data
37
SE 220 LSNi control unit
Operating voltage
9.6 V...30 V
Total current consumption including blocking
element at an input voltage of 9.6 V
- Restore LSN part
3.53 mA
- Restore additional
supply
41 mA
- Bolts being engaged
110 mA for 200 ms
- Bolts blocked
470 mA for 200 ms
Total current consumption including blocking
element at an input voltage of 28 V
- Restore LSN part
3.53 mA
- Restore additional
supply
30 mA
- Bolts being engaged
65 mA for 200 ms
- Bolts blocked
200 mA for 200 ms
Test input
(pull-up input resistor
on + 5 V)
Activate by connect-
ing 0 V. This input is
only intended for test
purposes, i.e. cables
may only be con-
nected temporarily
for the purpose of
performing a test.
Environmental condi-
tions
- Environmental class
2
- Protective system
IP 30
- Operating tempera-
ture
-5°C...+45°C
- Storage temperature -40°C...+85°C
Housing
- Material
ABS
- Color
RAL 9002
Dimensions (WxHxD)
135 x 160 x 35 mm
Weight 0.25
Kg
VdS approval
(Cl. C) for overall
system
G 106064, C
Blocking element
Max. distance between
bolt and counterpiece
4 mm
Bolt break force
approx. 1kN
Cable to
control unit
max. 6 m, 6-pin,
screened,
completely
sealed
Environmental condi-
tions
- Environmental class
3
- Protective system
IP 44
- Operating temperature -25°C...+55°C
- Storage temperature
-40°C...+85°C
Housing
- Material
ABS
- Color
RAL 9002
Weight
- Surface mounted mo-
dels
- Recessed mounted
models
0.45 Kg
0.40 Kg
Dimensions (WxHxD)
118 x 28 x 16 mm
Note on the blocking element:
SE 220
LSNi without bolt contact. If all the bolts of
all SE 220 LSNi units in a detection area are
to be activated simultaneously, the values
for "activated bolts" must be added together
when calculating power requirements. Up to
four SE 220 LSNi can be activated within
200 ms due to the time shift caused by the
LSN.