Element
Usage/Description
Show tests on the map
If this checkbox is selected, tests from subscriber's transmitter will
be displayed on the normal map screen as
OK
or
FAIL
icons,
signifying a successful test by a valid subscriber or an attempted
test transmission from a transmitter not in the
Subscriber
Database
. This checkbox doesn’t affect the display the subscriber
receives from a SE receiver or Alert Unit’s strobe. Typically, this
checkbox would be selected.
All Pager Confm Not
Reqd
If this checkbox is selected, the confirmation pager message is not
sent to the any of the pagers when the alarm is acknowledged by
an acknowledgement transmitter.
Suppress Lanyard
Alarm
If this checkbox is selected, the lanyard alarm is suppressed and
not reported.
Suppress Man Down
Alarm
If this checkbox is selected, the man down alarm is suppressed
and not reported.
Isolate WS from Alarm
This function is not available for this release.
Auto silence alarm in
'X' seconds
This field determines the length of time that the sirens and horns
will sound, before being automatically silenced by the Central
Console. When the sounders are automatically silenced in this way,
the Central Console remains in its “Alarm” mode. The numerical
value is in seconds, and it can be set between 0 and 9999.
Typically, this value would be set to prevent violating local noise
ordinances and it defaults to 240 seconds (4 minutes).
Recall operator in 'X'
seconds
This field determines the length of time before a "Recall" alert is
issued to the operator at the Central Console when an alarm is
being displayed. If neither the mouse nor any key has been
actuated for the specified length of time, the Console will trigger
the "Alarm" sound once. This feature prevents inadvertently
ignoring an active alarm event. The numerical value is in seconds,
and it can be set between 0 and 240. Typically, this would be set
to 60 seconds.
On outside tests, flash
strobe for 'X' seconds
This field controls the approximate length of time the strobe on an
Alert Unit will flash to signify a successful transmitter test. The
value is in seconds, and can be set between 0 and 15. Typically, it
is set to 5 seconds.
Man down delay timer
‘
X
’
seconds
This field controls the time that a transmitter must be in a man
down condition before a man down alarm is displayed. Typically it
would be set to 5 seconds. Setting this value too short will cause
inadvertent man down alarms to be generated.
Man down jitter timer
‘
X
’
seconds
This field controls the time that a transmitter will not be
considering any man down alarm if man down alarm is received
immediately after restore and before jitter time expire. This setting
will not be used in normal system.