Security Escort
System menus and dialogs | en
193
Robert Bosch (SEA) Pte Ltd
Technical Reference Manual
2018.03 | SE3v1.0 | DOC
Figure
10.21: Transponder current status dialog
Element
Usage/Description
Transponder
Selects the SE coordinator from the drop-down list.
Total Alarms Received
The total number of alarm messages received by the Central
Console from this SE coordinator since the data was last reset
(using the
[Reset Transponder Troubles]
button).
Total Tests Received
The total number of test messages received by the Central Console
from this SE coordinator since the data was last reset (using the
[Reset Transponder Troubles]
button).
Total Troubles
Processed
The total number of trouble messages received by the Central
Console from the SE coordinator and processed (see
Total
Troubles Shed
) since the data was last reset (using the
[Reset
Transponder Troubles]
button).
Total Troubles Shed
During certain rare occurrences, the communication traffic on the
SE coordinator links becomes excessive and threatens to increase
the system response time to tests and alarms. This can happen if
faults are reported at a very high rate. To avoid slow response in
such situations, the Central Console may go into a load shedding
mode in which it ceases to record and display trouble reports until
the communications traffic subsides. The
Total Troubles Shed
box
indicates the number of trouble messages that were not processed
since the last reset (using
[Reset Transponder Troubles]
button).
Successful Incoming
Messages
The total number of messages successfully received from this Se
coordinator.