en | System menus and dialogs
Security Escort
2018.03 | SE3v1.0 | DOC
Technical Reference Manual
Robert Bosch (SEA) Pte Ltd
Figure
10.22: Transponder parameter change dialog
Element
Usage/Description
Run silent
If selected, the SE receivers on this SE coordinator bus do
not sound an alarm. This includes alarms received during a
communications failure with the Central Console.
Optional parameter 2
This option is currently disabled and reserved for future
use.
Disable RS485
If selected, the RS485 bus on this SE coordinator is
disabled.
Disable Tamper
If selected, the tamper on this SE coordinator is disabled.
Disable RF
If selected, the radio frequency (RF) functionality on this SE
coordinator is disabled.
Optional Parameter 6
This option is currently disabled and reserved for future
use.
Comm fail to siren out
If this item is selected, the siren output on this SE
coordinator activates when a communications failure is
detected at the Central Console.
Verbose point reports
If selected, alarm and test reports include average levels
and packet count information. This extra information is for
diagnostic proposes only and is not required for system
operation. Since the additional data increases the system
traffic load leave this item unselected.