3 Positioning guidelines

In order to achieve the highest-possible annual energy 
yield, we recommend positioning the module so as to 
fulfill the following criteria:

 

Definitely align the solar module so as to avoid a 
shadowing effect (even to a temporary or partial 
extent: e. g. due to roof dormers, trees), since this 
can lead to damage in the solar modules (e. g. forma-
tion of „hot spots“), failure of the PV generator and 
loss of output.

 

Align the front of the solar module to the south.

 

Select the angle of inclination according to the local 
and structural factors (30° ± 15°). You will find spe-
cific data on optimum module positions in the perti-
nent specialized literature. The calculation of the 
angle of inclination can be based on the following 
formula: angle of inclination = latitude of the positio-
ning locality – 20°.

 

All modules of a photovoltaic generator are to be 
aligned at the same angle (horizontal as well as verti-
cal). In the event of angle deviations, separate fre-
quency converters are to be designated.

4 | Positioning guidelines

 

In order to ensure sufficient selfcleaning, the angle of 
inclination must amount to at least 10°.

 

For optimized selfcleaning, a 15° minimum angle of 
inclination is recommended.

 

Always ensure that the reverse side of the module is 
well ventilated.

 

To avoid increased strain of the modules due to wind 
load, it is necessary to observe minimum distances 
from building boundaries according to DIN 1055-4.

 

A concentration of sunlight on the modules via mir-
rors or lenses is prohibited.

 

Avoid contact with salty water!

 

The crystalline solar modules made by Bosch Solar 
Energy have been tested in accordance with the 
following norms for their response to contact with 
salty air:

  – IEC 61701: 1995
  – DIN EN 61701: 2000-08
  – IEC 60068-2-52. 

Please observe the test conditions indicated in the 
norms when using the modules in salty air.

Summary of Contents for -Si M 60 EU30123

Page 1: ... c Si M60 S I Bosch Solar Module c Si P60 Robert Bosch GmbH en Operating instructions Installation and Operation Guide Crystalline Solar Modules Bosch Solar Module c Si M 48 EU I Bosch Solar Module c Si M 60 EU Bosch Solar Module c Si M 60 S EU I Bosch Solar Module c Si P 60 EU Issue 02 2012 ...

Page 2: ...nd operation guide com pletely and carefully before you transport install and operate the solar modules It contains among other information important safety information which you must know When solar modules are used without observing all instructions in this guide all warranty and guarantee claims towards us shall lapse We reserve the right to update the information in this guide without prior no...

Page 3: ...one must reckon with the full atrest voltage of the modules that is to Important Notice say in the course of setup one must always exercise the greatest caution with regard to electrical faults e g short circuits The separation of conductors which carry direct current can lead to light arcs Therefore prior to performing any work on the solar system particular ly prior to separating the plug connec...

Page 4: ...ormula angle of inclination latitude of the positio ning locality 20 All modules of a photovoltaic generator are to be aligned at the same angle horizontal as well as verti cal In the event of angle deviations separate fre quency converters are to be designated 4 Positioning guidelines In order to ensure sufficient selfcleaning the angle of inclination must amount to at least 10 For optimized self...

Page 5: ...he clamp surface per attachment point on the mo dule must amount to at least 400mm Position of the installation drill holes in accordance with Illustrations 3 6 Per module four non corrosive screws and nuts and grommets with min 12 and max 14mm exterior diameters are to be used in accordance with Table 1 Installation guidelines 5 Important Notice The modules must be attached flush to the substruc ...

Page 6: ... 60 EU I Bosch Solar Module c Si M 60 S EU I Bosch Solar Module c Si P 60 EU Bosch Solar Energy AG l 4 mounting holes l 2 l 4 l l 7 l 7 l 4 mounting holes l 2 l 4 l l 7 l 7 Figure 1 Mounting area vertical Figure 2 Mounting area horizontal 6 Installation guidelines ...

Page 7: ...s 430 800 0 5 20 1660 2 800 1200 990 2 100 15 Ø4 36 Ø9 Ø9 4 x Mounting holes for grounding cable 340 20 20 100 Ø9 Ø4 2 Ø9 1000 0 5 990 2 1680 2 1000 4 x Module mounting holes 2 x Mounting holes for grounding cable 4 x Module mounting holes 988 2 812 0 5 1000 Ø4 5 Ø7 Ø7 22 5 22 5 423 75 1659 5 2 2 x Mounting holes for grounding cable 1343 2 988 2 817 0 5 263 1000 Ø7 Ø7 Ø4 5 22 5 22 5 4 x Module mou...

Page 8: ...f modules is serially switched to the stands to be switched parallel to these and that suitable measures for surge protection 8 Circuitry guidelines are taken e g strand fuse It must be ensured that the specified load capacity with regard to the reverse current IR 17 A at c Si M 60 and c Si M 48 16 A at c Si P 60 and c Si P 48 is not exceeded Under standard conditions a PV module can provide highe...

Page 9: ...oil grease or alcohol The solar plugs installed by the plant may not be removed In the course of the installation one must ensure the tensile relief of the module connector cables Manufac turer Module Version Positive Pole Negative Pole 11 EU xx011 Tyco Neutral 6 1394461 2 Tyco Minus 1394462 4 13 EU xx113 MC4 Plus PV KST4 MC4 Minus PV KBT4 14 EU xx014 MC3 Plus PV KST3 MC3 Minus PV KBT3 17 EU xx017...

Page 10: ...osion resistant materials Position of the grounding drill holes in accordance with Illustrations 3 6 7 Grounding Important Notice Defective or old solar modules must be appropriately disposed of These may not be disposed of in house hold waste Minimal maintenance and upkeep effort is required in order to maintain the optimum output of the solar mod ule In the interest of optimum system output we r...

Page 11: ...e of storage and transport it must be ensured that each solar module is sufficiently rein forced 10 Storage and transport Important Notice Storage and transport 11 The stacking of packaging units can cause damage to the solar modules and must definitely be avoided The solar modules are to be secured against overtur ning Layer pads must be used between the individual solar modules We recommend stor...

Page 12: ...ch Solar Module c Si M60 I Bosch Solar Module c Si M60 S I Bosch Solar Module c Si P60 Robert Bosch GmbH Bosch Solar Energy AG Robert Bosch Straße 1 99310 Arnstadt Germany Tel 49 0 361 2195 0 Fax 49 0 361 2195 1133 www bosch solarenergy de ...

Reviews: