- 5 -
610-4.998.115.270
A4 01.04.2004
Table of Contents
- Assembly
- Technical Data
- Exchanging the keypad in case of damage
- Connection plan SmartKey code keypad with integrated reader
➊
Before Assembly
Slits have been made in the side to accommodate the cable.
Empty pipe for the relocation is prepared.
For systems according to VdS guidelines, the recessed version is preferred
➋
Use a standard 55 mm recessed box or included surface box
outside the secured area near the door
at a maximum distance of 6 m from the control unit
at a minimum height of 1.20 m for systems according to VdS guidelines
if necessary, in combination with another recessed box beneath or next to one another for code keypad and
another reader
➌
First, assemble
only the sealed installation part with the cable
in the recessed or surface box. The screws
are fixed in the surface box with an adhesive strip.
The installation position of the installation part must be noted; see figure.
Recessed version
Surface version
Screw the installation part and box together here.
down
Screw the installation part and box together here.
Screw the installation part and box together here.
Screw the installation part and box together here.
down
WARNING
Assembly
SmartKey
Code keypad
with integrated reader
Installation Notes (GB)
Recessed version
Surface version