Solution 6000
Installation Manual
Device Programming
10-10
Bosch Security Systems 07/14 BLCC610I
Device > RF Devices >
RF Device Options
MENU 6-2-2
1
Display RF Tamper
Y
2
Report RF Tamper
Y
3
Report RF Low Battery
Y
4
Report Lost RF Devices
Y
5
Open Zone On Lost RF
N
6
Audible Keyfob Panic
Y
7
Report Keyfob Panic
Y
8
Keyfob Func Part On
Y
This menu option allows you to configure various options
and functions for RF devices connected to the system.
1)
Press [MENU] + [6] + [2] + [2]. The keypad will
display the current RF Device Options.
Display RF Tamper
Report RF Tamper
Report RF Low Battery
Press
OK ON OFF MENU
2)
Use the up and down arrow keys to highlight the
option then press the [ON] key to enable or the
[OFF] key to disable.
3)
Repeat Step 2 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Display RF Tamper
Setting this option will cause the keypad to display the
RF zone when a tamper condition occurs.
Report RF Tamper
Setting this option will cause the panel to send an RF
Device Faulted report to the base station when the
devices tamper curcuit is tripped. A restore report will be
sent when the tamper circuit is resealled.
Report RF Low Battery
Setting this option will cause the panel to send a report
to the base station when the RF device signals to the
panel that it has a low battery condition.
Report Lost RF Devices
Setting this option will cause the panel to send a report
to the base station if the panel detects that an RF device
is missing.
Open Zone On Lost RF
Setting this option will cause the panel to show a zone
fault on the keypad for any RF devices that are missing
Audible Keyfob Panic
Setting this option allows users who have RF keyfobs to
trigger an audible panic alarm via the keyfob.
Report Keyfob Panic
Setting this option will cause the panel to send a Panic
report to the base station when a panic alarm has been
initiated via a key fob.
Keyfob Func Part On
Setting this option will allow keyfob users to arm an area
or all areas of the system using function key 1 on the
keyfob.
Devices > RF Devices >
Add RF Keypad
MENU 6-2-3
Reserved for future use.
Delete RF Keypad
MENU 6-2-4
Reserved for future use.
View RF Device ID
MENU 6-2-5
This command allows you to trap and view a transmitters
I.D. number when it has been forgotten or it is no longer
legible on the transmitter label. The device being tested
must be compatible with the RF receiver fitted to the
panel.
1)
Press [MENU] + [6] + [2] + [5]. The system will then
begin waiting for a valid trigger signal.
Waiting for Trigger!
Press OK or MENU
2)
Trigger the transmitter by pressing any button on
the keyfob or by triggering the tamper switch on
any sensor.
Type = Keyfob
Ur1 User 1 Name
RFiD = 123456789
Press OK or MENU
3)
To test another transmitter, repeat step 2. A beep
will be heard each time a new RFID is received and
the new number will be displayed.