Solution 6000
Installation Manual
Programming Overview
4-10
Bosch Security Systems 07/14 BLCC610I
B A S I C S YS T E M O P E R AT I O N
T U R N I N G A N A R E A A L L O N
Use this function to turn an area All On. The control panel
is factory default only for one area. As soon as you turn
an area on, exit time will start. Exit time allows you to exit
the premises without sounding an alarm. The security
installer or a master PIN user can program the length of
exit delay time.
1)
Make sure that all zones are normal (not faulted).
2)
Enter your PIN, then press the [ON] key.
If your PIN
is valid and if all zones are normal, exit delay time will
start. You should leave now. If your control panel
detects a faulted zone, you should return it to
normal, or bypass the zone. During exit delay, you
may stop the area from turning on by entering your
PIN followed by the [OFF] key.
T U R N I N G A N A R E A PA R T O N / PA R T 2 O N
Use this function to turn an area Part On or Part 2 On. The
control panel is factory default only for one area. Part On
and Part 2 On turns on only part of the area, leaving the
rest of the area turned off.
Only the security company can program which zones are
monitored for Part On. A master user can program which
zones are monitored when a user turns an area Part 2 On.
Once you have turned an area Part On or Part 2 On,
exit delay time starts to count down. You should leave
all zones that are active before exit delay time expires.
Leaving active zones after exit delay expires causes an
alarm event. Use Part On or Part 2 On only when you want
part of an area turned on.
1)
Make sure that all zones are normal (not faulted).
2)
Enter your PIN, then press the [PART] key.
If your
PIN is valid and if all zones are normal, the keypad
will prompt you to select Part On or Part 2 On.
3)
Using the arrow keys, highlight Part On or Part 2
On then press [OK].
Exit delay time will start. You
should leave now. If your system has a faulted zone,
you should return it to normal, or bypass the faulted
zone. During exit delay, you may stop the system
from turning Part On by entering your PIN followed
by the [OFF] key.
4)
When exit time has expired, the keypad will display
the Part On icon.
i
Note
If you wish to cancel the exit delay time when turning
the area Part On/Part 2 On, press the [PART] key once
during the exit delay time.
T U R N I N G A N A R E A O F F
When the system is on, you must enter through a
designated entry door to prevent an alarm. Opening
a designated door (e.g. front door) will start entry time.
During entry time, the keypad will sound the Hi/Lo tone to
remind you to turn the area off. To turn the area off, enter
your PIN followed by the [OFF] key before the entry delay
time expires.
If you enter through the wrong door or fail to turn the
system off before the entry delay time expires, you may
sound an alarm. If an alarm occurs, silence the alarm
(by entering your PIN followed by the [OFF] key) and call
your security company to let them know that it is not an
emergency situation.
1)
Enter your PIN + [OFF] to turn the system (or area)
off. The keypad will no longer display the ‘Lock’ or
‘Part’ icons.
S I L E N C I N G A L A R M S
When the control panel has registered an alarm, the
keypad (s) and sirens will sound to alert personnel that an
alarm occurred. The keypad will scroll all alarms on the
keypad display for visual feedback. If you enter your PIN
before the system dials your security company, the alarm
report is cancelled (if programmed).
1)
Enter your PIN + [OFF] to silence any alarm and turn
the system off.
The keypad will continue to scroll all
alarm events that caused the alarm. This is called
alarm memory.
2)
To clear alarm memory, turn the area on and off
again (eg. PIN + [ON] + PIN + [OFF]).
AU TO M AT I C A R M I N G
Your system may have been programmed to automatically
turn one or more areas All On at a certain time of the day.
If for some reason you are still in the building when the
auto arming is taking place, it is possible to delay the
auto-on time (automatic arming time) by one hour simply
by entering your PIN during the auto-on pre-alert time.
The auto-on pre-alert time sounds the keypad buzzer to
warn you that the system will automatically turn All On.
Example:
If the control panel is programmed by your installer to
automatically turn All On at 6:00pm and the auto-on pre-
alert time starts beeping the keypad at 5:55pm, entering
your PIN between 5:55pm and 6:00pm will delay the auto-
on time by one hour and the auto-on pre-alert time will
again commence at 6:55pm. Therefore the system will
automatically turn All On at 7:00pm.