Solution 6000
Installation Manual
Input Programming
7-4
Bosch Security Systems 07/14 BLCC610I
ZO N E P R O P E R T I E S
Inputs > Zone Properties >
Zone Name
-
MENU 3-1-0
Z o n e
1 N a m e
This menu allows you to program the name for each zone.
Zone names can be up to 20 characters long.
1)
Enter [MENU] + [3] + [1] + [0] and use the up and
down arrows to highlight the Zone in the list then
press [OK]. Alternatively, you can enter the zone
number directly and press [OK].
2)
User the arrow and number keys to move and
change text. When the Zone Name is complete,
press [OK]. At any time you can press the [OFF] key
to clear the text from the current cursor position to
the end of the line.
Zone Name Zn1
Zone 1 Name
Press
OK to SAVE
i
Note
See Alpha Text Programming in Section 4 -
Programming Overview for further detail on entering
alpha text.
Inputs > Commands >
Smoke Sensor Reset
-
-
MENU 3-0-5
This command allows you to reset smoke sensors.
When initiated this command will cause any outputs
programmed as Event Type 49 — Smoke Sensor GND in
the chosen area to turn off for 10 seconds.
1)
Enter [MENU] + [3] + [0] + [5] and use the up and
down arrows to highlight the area that you want to
reset the smoke detectors in then press [OK].
Smoke Detector reset in
progress. Please wait
2)
The keypad will automatically return to the menu
when all smoke detectors in the area has been
reset.
i
Note
Smoke detectors must have the negative power
terminal connected to an output programmed as
Event Type 49 for this command to work.
ZO N E D E FAU LT TA B L E
The table below lists the default values for all zone parameters in the control panel. Zones marked as Not Used do not
require EOL resistors to be fitted.
Programming
Zone 1
Zone 2
Zone 3
Zone 4
Zones 5 - 16
Zones 17 - 144
Zone Name
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5 to 16
Zone 17 to 144
Zone Type
1 = Delay 1
5 = Handover
5 = Handover
5 = Handover
3 = Instant
0 = Not Used
Area Assignment
1
1
1
1
1
1
Pulse Count
0
0
0
0
0
0
Pulse Count Time
120
120
120
120
120
120
Door Assignment
0
0
0
0
0
0
Report Route
2
2
2
2
2
2
Reporting Options
Lockout Dialler
Y
Y
Y
Y
Y
Y
Report Alarm
Y
Y
Y
Y
Y
Y
Report Troubles
Y
Y
Y
Y
Y
Y
Report Bypass
Y
Y
Y
Y
Y
Y
Reserved
N
N
N
N
N
N
Reserved
N
N
N
N
N
N
Report Restores
Y
Y
Y
Y
Y
Y
Delay Reporting
N
N
N
N
N
N
Zone Options
Lockout Siren
Y
Y
Y
Y
Y
Y
Silent Alarm
N
N
N
N
N
N
Inverted Seal
N
N
N
N
N
N
Bypass Allowed
Y
Y
Y
Y
Y
Y
Sensor Watch
N
N
N
N
N
N
Armed In Part On
Y
Y
Y
Y
Y
Y
No EOL Required
N
N
N
N
N
N
Test On Exit
N
Y
Y
Y
Y
Y
Table 21: Zone Defaults