background image

TC9346A Series 

Instruction Manual

EN

Environmental
Enclosure

Summary of Contents for TC9346A Series

Page 1: ...TC9346A Series Instruction Manual EN Environmental Enclosure ...

Page 2: ...NCE 12 5 2 TROUBLESHOOTING 12 6 0 SPECIFICATIONS 14 LIST OF ILLUSTRATIONS Figure Page 1 Exploded Assembly Diagram for Blower and Circuit Board 5 2 TC9346A Series Input Wiring Diagram 9 3 Component Locations for Optional Circuit Board 12 4 Layout of Traces on Optional Circuit Board 12 5 Wiring Diagram for Optional Circuit Board O I PCB 13 6 TC9346A Dimension Drawing 15 LIST OF TABLES Table Page A 2...

Page 3: ...lacement repair of this unit s electrical components conduct a resis tance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry 5 The installation method and materials should be capable of supporting four times the weight of the enclosure pan tilt camera and lens combination The product and or manual may bear the following marks This symb...

Page 4: ...er kit 120 VAC 15 watts BK57 2 Blower kit 24 VAC 10 watts BK57 3 Blower kit 230 VAC 15 watts HK57 1 Heater kit 120 VAC 90 watts HK57 2 Heater kit 24 VAC 50 watts HK57 3 Heater kit 230 VAC 70 watts O I PCB Circuit board with thermostats O I LPP Preset position lens wire harness must be used with O I PCB O I OUTLET 120 VAC electrical outlet must be used with O I PCB SS5729 Sun shroud TI57 Thermal in...

Page 5: ...3 Models Only If you are installing the enclosure in a marine or high moisture environment make the following modifications to your enclosure Refer to Figure 1 for an exploded assembly diagram of the blower assembly a Disconnect the electrical plug 3 from the fan 4 b Remove the three sets of screws and washers A B and C that secure the fan plate 5 and fan 4 to the enclosure Figure 1 Exploded Assem...

Page 6: ...e provided in the parts bag You can mount the camera to either side of the U shaped sled depending on the camera height required 6 There are two threaded mounting holes on the bottom of the enclosure Mount the enclosure to a pan tilt assembly or fixed mount with 1 4 20 screws with threads that do not exceed 5 8 of an inch 1 59 cm in length not supplied with the enclosure 7 Install the sled and cam...

Page 7: ... the power supply section of the circuit board When the power requirements are different connect the wires from the two pin plug which is supplied as loose equipment to the camera as follows Brown AC HI Blue AC NT Connect the plug to the CAM 2 socket on the circuit board 12 Wire power to the enclosure to operate the camera TC9346A Model Only Wire power directly to the camera If you are using 24 VA...

Page 8: ... circuit board If the camera s power is connected to CAM 1 on the circuit board add the camera s wattage to the power consumption of the accessories to determine the size of wire to use If you are using 24 VAC refer to Table A to determine the size of wire to use Here are the wattages for the accessories Defrosters for all enclosures 30 watts Wipers for all enclosures 15 watts Blowers for 120 VAC ...

Page 9: ... WIPEON WASH ON W W W W DEF CAM 1 HTR FAN FAN 1 1 1 1 P7 P5 P2 TB2 TH1 TH2 TB4 P6 TB3 HTRS SPARES AC HI NT GND 1 2 1 1 2 3 4 5 6 7 8 9 10 PCB9000276 O I PCB LENS CONTROL LENS J1 5 INPUTS 1 LENS COM FOCUS ZOOM IRIS PRST COM PRST FOCUS PRST ZOOM PRST HI CAM CAM TB1 1 P1 P3 1 1 2 CAM 2 WHT ORG WHT BRN WHT RED WHT BLU BLK WHT YEL WHT RED WHT GRN WHT LENS CONN W PRESETS SUPPLIED WITH PCB LENS CONN PLUG...

Page 10: ...6 70 40 64 102 163 258 411 12 19 31 49 78 125 80 35 56 89 142 226 360 10 17 27 43 68 109 90 31 50 79 126 201 320 9 15 24 38 61 97 100 28 45 71 114 181 288 8 13 21 34 55 87 110 25 41 65 103 164 261 7 12 19 31 49 79 120 23 37 59 95 150 240 7 11 17 28 45 73 130 21 34 55 87 139 221 6 10 16 26 42 67 140 20 32 51 81 129 205 6 9 15 24 39 62 150 18 30 47 76 120 192 5 9 14 23 36 58 160 17 28 44 71 113 180 ...

Page 11: ...o turn the fan on between 77 and 93 F 25 and 34 C and to turn the fan off be tween 62 and 78 F 17 and 26 C If your enclosure has thermostatically controlled heaters or defroster the thermo stat is set to turn them on between 42 and 58 F 6 and 14 C and to turn them off between 72 and 88 F 22 and 31 C ...

Page 12: ... the enclosure remove the two screws in the vent grill b Remove the vent grill and take out the filters c Clean the filters with warm water and mild detergent dry thoroughly and replace them in the grill d Reinstall the vent grill To order replacement filters use the part number EH550010045 5 2 TROUBLESHOOTING If your enclosure has the optional circuit board O I PCB and you need to trouble shoot i...

Page 13: ...13 ENCLOSURE CIRCUIT BOARD REFER TO FIGURE 3 FOR COMPONENT LOCATIONS Figure 5 Wiring Diagram for Optional Circuit Board O I PCB ...

Page 14: ...watts Defroster 1 2 3 30 watts Blower 1 3 15 watts Blower 2 10 watts Wiper 1 2 3 15 watts MECHANICAL Construction Aluminum 0 080 inch 0 02cm thick Enclosurebodyandlid Finish Polyester vinyl powder coat Cable Entry Two UL approved glands on bottom of enclosures maxi mum cable diameter 0 47 inch 1 19 cm Will accept 1 2 inch 1 27 cm conduit without glands Window Glass 0 25 inch 0 64 cm thick Window V...

Page 15: ...n vent cover plates are used Environment Indoor outdoor 10 to 120 F 23 to 49 C Design and product specifications subject to change without notice C A B 3 06 7 78 8 60 21 84 6 19 15 72 10 55 26 79 5 25 13 35 4 25 10 79 A B C 29 00 14 50 32 50 73 66 36 83 82 55 NOTE VALUES IN PARENTHESES ARE CENTIMETERS ALL OTHERS ARE INCHES ...

Page 16: ...urity Systems Inc 850 Greenfield Road Lancaster PA 17601 USA Tel 800 326 3270 Fax 1 717 735 6560 www boschsecuritysystems com Bosch Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands Tele 31 40 27 80000 Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Republic of Singapore Tel 65 6 319 3486 ...

Reviews: