7.11 The deposit drains by itself (with device off)
7.11.1 Description of the problem
The water deposit slowly empties with the device switched off (the
device absorbs water from the deposit while cooling).
7.11.2 Cause of the problem
The defect is due to a lack of ventilation of the boiler; thus, during its
cooling, a vacuum is generated inside the boiler which absorbs the
water from the deposit. The symptom the user detects is that with the
device switched off, the water deposit gradually drains.
The ventilation of the boiler must be through the ACE (air check
valve), which allows absorption of outside air during cooking and
during heating, prevents air from escaping to accumulate pressure in
the boiler. Possible defects which prevent the entry of air during
cooling would, therefore, be:
A- Electrovalve outlet obstructed: should be permanently open.
B- Air check valve obstructed by lime or rust (the ball cannot
move freely)
C- Flow regulator obstructed
7.11.3 Solution
Check the indicated components (A, B y C) and change those which
are obstructed or defective.
A
B
C