7.12 Inner tank seal damaged
7.12.1 Problem
description
In devices whit FD<8907, the seal is damaged
7.12.2 Cause of the problem
Wrong cleaning by client (vinegar basis)
7.12.3 Solution
Change the seal.
From FD8907, the seal material was changed from NBR to EPDM.
7.13 Steam regulator breakages
7.13.1 Problem
description
In devices whit FD<8904, the steam regulator is broken.
Summary of Contents for TDS2510